The Effect of Gabraun and Distilled water on Corrosion rate of brass and Carbon Steel specimens when immersed together in one beaker
No Thumbnail Available
Date
2021
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
جامعة سبها
Abstract
The aim of this work was to study the effect of Gabraun`s water on corrosion of
yellow copper (Brass) and carbon steel. The corrosion tests were carried out in this
study at room temperature. The test solution (electrolyte) used in this study was
Gabraun and Distilled water samples. From the obtained results, it was found that the
weights of all the brass specimens immersed in Gabraun`s water were decreased. The
color of the Gabraun water samples that was used for Brass specimens corrosion tests
was changed to dark blue color, this color was attributed to copper sulfate resulted
from corrosion reaction, while for carbon steel the color of the water did not change
and some of the specimens weights were decreased and the others were increased.